Product Number | PM-U25 |
Part Number | PMU25 |
Applicable regulations and certifications | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), ISO 13849-1 (Category 1, PLc) (Note), UL/c-UL certification |
(Note) : Conformed from December 2021 production. | 0.05 mm 0.002 in or less |
Sensing range | 6 mm 0.236 in (fixed) |
Minimum sensing object | 0.8 × 1.2 mm 0.031 × 0.047 in opaque object |
Hysteresis | 0.05 mm 0.002 in or less |
Repeatability | 0.01 mm 0.0004 in or less |
Supply voltage | 5 to 24 V DC ±10 % Ripple P-P 10 % or less |
Current consumption | 15 mA or less |
Output | NPN open-collector transistor |
・Maximum sink current: 50 mA | Orange LED (lights up under light received condition) |
・Applied voltage: 30 V DC or less (between output and 0 V) | 3 |
・Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) | IP64 (IEC) |
Output:Output operation | Incorporated with 2 outputs: Light-ON / Dark-ON |
Output:Short-circuit protection | Incorporated |
Response time | Under light received condition: 20 μs or less |
Under light interrupted condition: 80 μs or less | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
(Maximum response frequency: 3 kHz)(Note) | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
(Note) : Refer to the note on the specification page for the response frequency. | 10 to 2,000 Hz frequency, 1.5 mm 0.059 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each |
Operation indicator | Orange LED (lights up under light received condition) |
Pollution degree | 3 |
Protection | IP64 (IEC) |
Ambient temperature | -25 to +55 ℃ -13 to +131 ℉ (No dew condensation or icing allowed), Storage: -30 to +80 ℃ -22 to +176 ℉ |
(Note) : In case is used at an ambient temperature of +50 ℃ +122 ℉, or more, make sure to mount it on a metal body. | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
(Note 1) : If the cable is extended to 20 m 65.617 ft or longer, confirm that the supply voltage at the end of the cable attached to the sensor is 4.5 V or higher.
(Note 2) : For safety applications, do not exceed 30 m 98.425 ft. |
Ambient humidity | 5 to 85 % RH, Storage: 5 to 95 % RH |
Ambient illuminance | Fluorescent light: 1,000 â„“x at the light-receiving face |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 2,000 Hz frequency, 1.5 mm 0.059 in double amplitude (maximum acceleration 196 m/s2) in X, Y and Z directions for two hours each |
Shock resistance | 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions three times each |
Emitting element | Infrared LED (Peak emission wavelength: 855 nm 0.034 mil, non-modulated) |
Material | Enclosure: PBT
Display section: Polycarbonate |
Cable | 0.09-mm2 4-core cabtyre cable, PVC, 1 m 3.281 ft long |
Wiring length | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
(Note 1) : If the cable is extended to 20 m 65.617 ft or longer, confirm that the supply voltage at the end of the cable attached to the sensor is 4.5 V or higher.
(Note 2) : For safety applications, do not exceed 30 m 98.425 ft. |
Weight | Net weight: 10 g approx
Gross weight: 15 g approx. |
Country of origin | China |