  • Brand : Panasonic
  • Supply Voltage : 12 to 24 V DC ±10 %, Ripple P-P 10 % or less
  • Output : PNP open-collector transistor
  • Connecting method : Cable

28,485.00 32,500.00 GST Extra

1 in stock

The Panasonic HG-C1400-P Micro Laser Distance Sensor is a precise measurement tool designed to meet EMC Directive Compliance and FDA Standards, ensuring accuracy and reliability in various applications. With a measurement center distance of 400 mm and a measuring range of ±200 mm, it offers exceptional versatility in distance measurement tasks.

Featuring a robust construction with an aluminum die-cast enclosure and an acrylic front cover, the Panasonic HG-C1400-P Micro Laser Distance Sensor is built to withstand demanding industrial environments. Operating effectively in ambient temperatures ranging from -10 to +45 ℃, it ensures reliable performance in various environments. Additionally, it boasts an IP67 rating for protection against dust and water ingress.

Equipped with a red semiconductor laser Class 2, the HG-C1400-P delivers precise measurements. It has a maximum output of 1 mW and an emission peak wavelength of 655 nm. Its control output features PNP open-collector transistors. This ensures seamless integration into control systems. It offers flexibility with either Light-ON or Dark-ON operation modes.

Our engineers acts wisely inputted all the required details of this sensor in accordance with the datasheet. Nevertheless, it’s imperative to recognize that errors may arise during this process. Despite our sincere efforts, it’s important to remain cautious. Inaccuracies can still occur nonetheless.

IndustryShoppy.in is your one-stop destination for all industrial automation needs. With a vast array of products including sensors, HMIs, PLCs, and more, we cater to diverse industries with top-quality solutions. Our user-friendly platform ensures a seamless shopping experience, while our commitment to reliability and customer satisfaction sets us apart. Explore our comprehensive range and elevate your operations with IndustryShoppy.in today!

Facebook, Youtube

SKU: NTSSEN00359 Category: Tags: , ,
Weight 450 g
Dimensions 19 × 11 × 11 cm
Brands

Panasonic

Condition

New

Country of Origin

Japan

BrandPanasonic
Product NumberHG-C1400-P
Part NumberUHGC1400P
Applicable StandardEMC Directive Compliance, FDA Standard
Measurement Center Distance400 mm 15.748 in
Measuring Range±200 mm 7.874 in
Repeatability300 μm 11.811 mil (Measuring distance 200 to 400 mm 7.874 to 15.748 in)
800 μm 31.496 mil (Measuring distance 400 to 600 mm 15.748 to 23.622 in)
Linearity±0.2 % F.S. (Measuring distance 200 to 400 mm 7.874 to 15.748 in)
±0.3 % F.S. (Measuring distance 400 to 600 mm 15.748 to 23.622 in)
Temperature Characteristics0.03% F.S./℃
Light SourceRed semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ]
Max. output: 1 mW
emission peak wavelength: 655 nm 0.026 mil
(Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
Beam Diameterø500 μm 19.6851 mil approx.
(Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
Supply Voltage12 to 24 V DC ±10 %, Ripple P-P 10 % or less
Current Consumption40 mA or less (at 24V DC supply voltage)
65 mA or less (at 12V DC supply voltage)
Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage)
Control OutputPNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: 30 V DC or less (Between control output to +V)
- Residual voltage: 1.5 V or less (At 50 mA source current)
- Leakage current: 0.1 mA or less
Control Output: Output OperationEither Light-ON or Dark-ON
Control Output: Short-Circuit ProtectionIncorporated (Auto reset type)
Analogue Output: Analog Voltage Output• Output range: 0 to 5 V (at alarm: +5.2 V)
• Output impedance: 100Ω
Analogue Output: Analog Current Output• Output range: 4 to 20mA (at alarm: 0mA)
• Output impedance: 300Ω or less
Note : Analog current output has been added from shipment in August 2016.
Response TimeSwitchable between 1.5 ms / 5 ms / 10 ms
External InputPNP non-contact input
- Input conditions
Invalid: 0 to +0.6 V DC or Open
Valid: +4 to +V DC
- Input impedance: 10 kΩ approx.
Pollution Degree2
Operating Altitude2,000 m 6561.680 ft or less
ProtectionIP67 (IEC)
Ambient Temperature-10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉
Ambient Humidity35 to 85 % RH, Storage: 35 to 85 % RH
Ambient IlluminanceIncandescent light: 3,000 â„“x or less at the light-receiving face
Vibration Resistance10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock Resistance500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Cable5-core composite cable, 2 m 6.5617 ft long
Cable ExtensionExtension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
MaterialEnclosure: Aluminum die-cast
Front cover: Acrylic
Weight (Typ.)Net weight: 35 g approx. (without cable), 85 g approx. (including cable)
Regulatory Compliance and CertificationCE Marking (EMC Directive, RoHS Directive), FDA Regulations, UL/c-UL Certification